completed 12/2025
The Department of Lighting Technology at the Technical University of Ilmenau was commis-sioned by BG ETEM to investigate whether the flicker perceptibility of 1,000 Hz against a light background, as demonstrated in Project 23-004, are reproducable against a dark background. However, against a dark background, the human eye is more sensitive to flicker, meaning that even 1,400 Hz was still perceptible with a 25 per cent probability.
In laboratory experiments, instead of a black dot on a white turntable, a white dot on a black turn-table against a dark background was used. This also rotated at the usual speed of hand movements. The light was varied in terms of illuminance, the frequency of pulse width modulation (PWM), the duty cycle (the ratio of on-to-off time), and the modulation depth. For each situation, the subjects had to indicate whether they could detect the light flickering
Younger subjects are more sensitive to flicker. With of a white dot on a black background, frequencies up to 1,400 Hz were still detectable with a 25 per cent probability. It is therefore recommended that the international limit values, technical workplace regulation ASR A3.4, and the DGUV’s current guideline FBVW-203 be revised, particularly with regard to dimmed conditions.
-cross sectoral-
Type of hazard:work-related health hazards, design of work and technology, unfavorable, adverse work environment
Catchwords:lighting, ergonomics, radiation
Description, key words:Flicker, light, stroboscopic effect, accident hazard, perception, migraine
Project UVT-BGETEM23-004: Stroboscopic effect as a function of duty cycle and environmental conditions
FBVW-203: Wenn der Schein trügt – Gefahren durch Lichtflimmern (in German)