News
Research
Technical information
Databases hazardous substances
Practical solutions
Testing/Certification
Publications
Events
About us
> Technical...
> Nanoparticle...
> Protective measures
Measurement of the particle number concentration during the use of nanomaterials

Enlarge (448 kB)

Measurement of the particle number concentration during the use of nanomaterials; figure: IFA

Mandatory sign: respiratory protection

Mandatory sign: respiratory protection

Mandatory sign: protective overall

Mandatory sign: protective overall

Contact:

Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung (IFA)
Division 3
Dr Markus Berges
Alte Heerstr. 111
53757 Sankt Augustin
Germany
Phone: +49 2241 231-2579
Fax: +49 2241 231-2234

Protective measures against ultrafine aerosols and nanoparticles at the workplace

Conclusion:

The studies conducted to date show that the protective measures commonly taken against dusts are also effective against ultrafine particles and nanoparticles. In the context of risk assessment and the specification of protective measures, the priority of measures as set out in Section 9 of the German regulation on hazardous substances (Gefahrstoffverordnung) must be observed. In particular, Annex III No. 2 concerning particulate hazardous substances, Section 2.3 must be implemented in conjunction with technical rule TRGS 500 Sections 5.2.2 and 6.2.3. Assessment criteria are proposed for evaluation of the effectiveness of the measures. All other obligations under the Gefahrstoffverordnung, such as those concerning the instruction of employees or occupational medical check-ups, are not affected by the fact that a substance is present in nanoparticulate form, but should be observed as normal.

Engineered protective measures

Owing to nanoparticles' new and in some cases surprising properties, it is frequently assumed that the usual OSH protective measures would not be effective against nanoparticles and ultrafine particles. Where filtration measures (such as breathing masks or air collection installations) are used, the image of a sieve is frequently cited through the large holes of which the small particles would slip. This assumption is not consistent with physical principles, however: particles larger than 300 nm are most effectively separated by impaction on the filter material, entrapment by the filter material, or sedimentation owing to gravity. For particles smaller than 300 nm, separation by diffusion (Brownian movement) and electrostatic forces becomes increasing relevant with decreasing size [1]. It can therefore be asserted as a rule that technical measures which are effective against dusts in general are also suitable for the elimination of nanoparticles and ultrafine particles [2].

Results of measurements concerning the effectiveness of filters

In the course of workplace measurements involving possible exposure to multiwalled carbon nanotubes, i.e. nanomaterials containing carbon, Han et al. and Yeganeh et al. reported in 2008 that conventional engineered protective measures appeared to be effective [3; 4].

Information on protective measures

An illustrative description of safe processes and of the protective measures employed in them for the handling of nanoparticles can be found in the brochure entitled "First Results for Safe Procedures for Handling Nanomaterials" [5]. It contains the results of the Nanosafe-2 project funded by the European Union.

During tasks involving dusts, Annex III (2) of the Gefahrstoffverordnung must be observed:

  • Installations, machinery and equipment emitting dust must be equipped with effective dust collection facilities, or other measures must be taken to prevent the release of dust.
  • The dust must be prevented from spreading to unaffected working areas.
  • Dust must be collected if possible in full at the point of emission or creation and disposed of safely; exhausted air must be routed such that as little dust as possible enters the breathing air of employees; the exhausted air may be returned to the working area only once it has been adequately purified.
  • The settling of dust deposits must be prevented. If this is not possible, dust deposits should be removed by means of damp or wet methods or by suitable vacuum cleaners or dedusting devices; dry sweeping or the use of compressed air to blow dust deposits away is not permissible.

Organizational protective measures

Tasks involving dusts are subject to the following rules in accordance with Annex III (2) of the Gefahrstoffverordnung:

  • Consideration must be given to the dust-raising behaviour.
  • Machinery and equipment must be selected and operated in such a way that as little dust as possible is released.
  • During commissioning of equipment for the filtration, collection and precipitation of dusts, its adequate effectiveness must be demonstrated.
  • The equipment must be inspected for its serviceability, maintained, and if necessary repaired at least once each year; the inspections must be documented.

Dust-intensive tasks are subject to the following rules in accordance with Annex III (2) of the Gefahrstoffverordnung:

  • Exposure must be kept as brief as possible.
  • The employees must wear the protective clothing provided.
  • Washrooms and separate storage facilities for work and normal clothing must be provided.

For tasks involving particulate nanomaterials, additional protective measures are compulsory:

  • Checks must be performed of whether particulate nanomaterials can be bound in liquid or solid media (dispersions, pastes, compounds).
  • The scope must be explored for performing processes in enclosed apparatus.
  • The employees must be instructed concerning the particular physical and chemical properties of nanomaterials and provided with up-to-date information concerning the associated health risks.
  • The number of employees at risk of exposure must be limited.
  • The hazard areas must be demarcated. Access must be prohibited for unauthorized persons.

Personal protective measures

Insights into the effectiveness of conventional personal protective measures have already been provided by the measurements conducted by the IFA (formerly BGIA) in 2001 [6] regarding the penetration of certain respiratory filter masks by sodium chloride particles (< 100 nm). Typical Class P2 and P3 glassfibre filters exhibited a permeability of only 0.2% and 0.01% respectively for the particle count.

Rengasamy et al. [7] used silver nanoparticles (4 to 30 nm) and sodium chloride particles (20 to 400 nm) in order to test NIOSH-tested (N95, P100) and CE-compliant (FFP2, FFP3) respiratory filter masks. The filter materials employed complied with the requirements stated in the standards. The Nanosafe 2 project confirmed the effectiveness of breathing masks, disposable protective overalls and gloves against graphite nanoparticles (20 to 100 nm) [8].

It is recommended that personal respiratory protection (e.g. filter class P3 or P2 respiratory protection) be worn when engineered measures (see above) are unable to prevent release of the nanoparticles. The breathing masks must seat tight against the face. The applicable restrictions upon wearing time and provisions governing occupational medical check-ups must be observed when respiratory protection is worn.

Attention must be paid to the adequate mechanical stability of gloves and to damage to the glove material in order to prevent skin contact. The way in which gloves are put on and removed and their overlap with other protective clothing are more relevant to possible skin contact than the permeation properties of the material. Woven protective clothing materials offer poorer protection than membrane materials. Additional protection against chemicals may be necessary under certain circumstances.

top

how to...

Literature and further information

weitere_informationen_170
  • [1] Hinds, W.: Aerosol technology: Properties and behavior and measurement of airborne particles. 2nd edition. New York, NY: Wiley-Interscience,1999
  • [2] NIOSH Publication
  • [3] Han, J. H. et al.: Monitoring multiwalled carbon nanotube exposure in carbon nanotube research facility. Inhal. Toxicol. 20 (2008), p. 741-749.
  • [4] Yeganeh, B. et al.: Characterization of airborne particles during production of
    carbonaceous nanomaterials. Environ. Sci. Technol. 42 (2008), p. 4600-4606.
  • [5] Project Nanosafe 2, Dissemination Report
  • [6] Riediger, G; Möhlmann, C.: Ultrafeine Aerosole an Arbeitsplätzen - Konventionen und Beispiele aus der Praxis. Gefahrstoffe - Reinhalt. Luft 61 (2001) No. 10, pp. 429-434.
  • [7] Rengasamy, S.; Eimer, B.C.; Shaffer, R.E.: Comparison of nanoparticle filtration performance of NIOSH-approved and CE-marked particulate filtering facepiece respirators. Ann. Occup. Hyg. 53 (2009) No. 2, p. 117-128.
  • [8] Dissemination Report: Are conventional protective devices such as fibrous filter media, cartridge for respirators, protective clothing and gloves also efficient for nanoaerosols?